HOME COMPANY LINKS FAQS HELP CONTACT US SITE MAP
MetaSystem UK Website
Search
VEHICLE AREA MOTORCYCLE AREA DEALER AREA PRESS AREA
VEHICLE AREA

 Vehicle Area / Vehicle Area  / Operating Instr... 

M750T Operating Instructions

To arm the system :Press the button on the original remote control unit. The red LED will flash and the system will be armed after 25 seconds.

To arm the system excluding interior sensors :Turn the ignition key on 2 times in sequence and arm the system with the original remote control within 15 seconds.

To disarm the system : Press the button on the original remote control unit. The red LED will turn off.

Alarm Memory :On placing the system in the disarm condition, the alarm memory feature is automatically activated. If the system has been triggered during the previous armed condition, the LED will indicate the trigger input responsible, for a period of 35 seconds as follows :

1 flash every 6 seconds- interior movement sensors

2 flashes every 6 seconds- door input

3 flashes every 6 seconds- bonnet/boot input

4 flashes every 6 seconds- ignition input

On turning the starter key, the memory is reset.

Emergency :The electronic emergency key can be used to take the alarm system off-line.

Click on the link below for printable version

METASYSTEM GROUP